- Pick up from our Store
To pick up today
Free
- Courier delivery
Our courier will deliver to the specified address
TBD
This NL 6000 Series UTM used for the mechanics property test such as the tensile, bending, compression and etc to various metallic and non-metallic materials. The testers have been developed according to BS EN 10002-1,ISO 7500-1 & ASTM A370 “Metal Tensile Test Method” with the adoption of the electro-hydraulic servo control and electronic measurement. It can automatically process the test result for statistical purpose and print default or user-defined test report.
To pick up today
Free
Our courier will deliver to the specified address
TBD
Tensile & Compression
This NL 6000 Series UTM used for the mechanics property test such as the tensile, bending, compression and etc to various metallic and non-metallic materials. The testers have been developed according to BS EN 10002-1,ISO 7500-1 & ASTM A370 “Metal Tensile Test Method” with the adoption of the electro-hydraulic servo control and electronic measurement. It can automatically process the test result for statistical purpose and print default or user-defined test report.
NL 6000 Series UTM use the micro-computer automatic data collection and processing, real time display of the test data and curves. It has the functions such as unlimited storage of test result in the computer, printing the test results and curves, processing the batch test result report, managing the database and so on. It also has the network interface. It can automatically seek the multiple technical parameters such as elastic module E upper yield strength ReH, lower yield strength REL, stipulated non-proportional elongation intensity Rr, tensile strength Rm, stipulated total elongation intensity Rt, yield point percentage elongation and etc.
NL 6000 Series UTM have the features such as the high precision, advantage performance, high reliability, convenient operation and etc.
OPERATION DISPLAY
SAFETY FEATURES
The system includes the followings safety features
CONTROL & DATA PROCESSING SOFTWARE
UNIQUE FEATURE
Brand |
Nl Test |
---|---|
Model number |
NL 6000 X / 013N |
Load Capacity |
1000 kN |
---|---|
Machine Class |
Class 1 |
Max. Compression Space |
600 mm |
Max. Tensile Space |
700 mm |
Piston Stroke |
200 mm |
Relative Error of Indicated Value |
±1% |
Effective Measurement Range |
1% – 100 % F S (Full Range without binning) |
Deformation Measurement Range |
1% – 100 % F S |
Relative Error of Deformation Indication |
±1% |
Relative Error of Displacement Indication |
±1% |
Relative Error of Stress Rate Control |
±2% |
Relative Error of Displacement Rate Control |
±1% |
Strain Rate Control Adjustment Range |
0.00025/s / 0.0025/s |
Relative Error of Strain Rate Control |
±2% |
Force, Deformation, & Displacement Retention Control |
0.3% – 100% F S |
Relative Error of Force, Deformation & Displacement Retention Control |
≤1% |
Girder Lifting Speed |
320 mm / min |
Effective Distance Between 2 Column |
455 mm |
Round Specimen Size |
Ø14 – Ø45 mm |
Flat Specimen Size |
Max. 40 mm Thick |
Size of Compression Platen |
Ø225 mm |
Dimension (Frame) |
810 x 700 x 2350 mm (LxWxH) |
Dimension ( Control Console) |
790(L) x 730(W) x 1600(H) mm |
Weight (Control Console) |
300 kg |
Weight ( Frame) |
2650 kg |
Voltage Supply |
380~415V, 3Ph,4kW,8.1A, 50/60 Hz |
In stock
Brand |
Nl Test |
---|---|
Model number |
NL 6000 X / 016H |
Max. Test Capacity |
2000 kN |
Machine Class |
Class 1 |
Relative Error of Indicated Value |
±1% |
Effective Measurement Range |
1% – 100 % F S (Full Range without binning) |
Deformation Measurement Range |
1% – 100 % F S |
Relative Error of Deformation Indication |
±1% |
Relative Error of Displacement Indication |
±1% |
Relative Error of Stress Rate Control |
±2% |
Relative Error of Displacement Rate Control |
±1% |
Strain Rate Control Adjustment Range |
0.00025/s / 0.0025/s |
Relative Error of Strain Rate Control |
±2% |
Force, Deformation, & Displacement Retention Control |
0.3% – 100% F S |
Relative Error of Force, Deformation & Displacement Retention Control |
≤1% |
Girder Lifting Speed |
350 mm / min |
Max. Compression Space |
650 mm |
Max. Tensile Space |
800 mm |
Effective Distance Between 2 Column |
590 mm |
Piston Stroke |
250 mm |
Round Specimen Size |
Ø20 – Ø70 mm |
Flat Specimen Size |
Max. 50 mm Thick |
Size of Compression Platen |
240 mm x 240 mm |
Dimension (Frame) |
1200(L) x 900(W) x 2940(H) mm |
Dimension ( Control Console) |
790(L) x 730(W) x 1600(H) mm |
Weight (Control Console) |
300 kg |
Weight ( Frame) |
6000 kg |
Voltage Supply |
380~415V, 3Ph,4kW,8.1A, 50/60 Hz |
In stock
Brand |
Nl Test |
---|---|
Model number |
NL 6000 X / 015H |
Load Capacity |
300 kN |
Machine Class |
Class 1 |
Max. Compression Space |
600 mm |
Max. Tensile Space |
700 mm |
Piston Stroke |
200 mm |
Relative Error of Indicated Value |
±1% |
Effective Measurement Range |
1% – 100 % F S (Full Range without binning) |
Deformation Measurement Range |
1% – 100 % F S |
Relative Error of Deformation Indication |
±1% |
Relative Error of Displacement Indication |
±1% |
Relative Error of Stress Rate Control |
±2% |
Relative Error of Displacement Rate Control |
±1% |
Strain Rate Control Adjustment Range |
0.00025/s / 0.0025/s |
Relative Error of Strain Rate Control |
±2% |
Force, Deformation, & Displacement Retention Control |
0.3% – 100% F S |
Relative Error of Force, Deformation & Displacement Retention Control |
≤1% |
Girder Lifting Speed |
320 mm / min |
Effective Distance Between 2 Column |
375 mm |
Round Specimen Size |
Ø10 – Ø32 mm |
Flat Specimen Size |
Max. 20 mm Thick |
Size of Compression Platen |
Ø150 mm |
Dimension (Frame) |
800(L) x 600(w) x 2100(H) mm |
Dimension ( Control Console) |
790(L) x 730(W) x 1600(H) mm |
Weight (Control Console) |
300 kg |
Weight ( Frame) |
1850 kg |
Voltage Supply |
380~415V, 3ph, 1.5kW, 6.1A, 50/60 Hz |
In stock
Weight | 250 kg |
---|---|
Dimensions | 49 × 79.5 × 175 cm |
Brand |
Nl Test |
Model number |
TT 6000 X / 019N |
Max Test Force |
50 kN |
Structure Type |
Twin Rigid Column with Twin High Precision Ball Screw |
Trailing Space |
950 mm (exclude fixtures) |
Width Space |
400 mm |
Test Force Accuracy |
±0.5% |
Test Speed Range |
0.01 – 500 mm/min |
Load Resolution |
1/100 000 |
Force Accuracy |
≤0.5% |
Displacement Resolution |
1/1000 |
Displacement Accuracy |
≤0.5% |
Resolution of Metal Extenders |
1/1000 |
Accuracy of Metal Extenders |
≤0.5% |
Accuracy of Extenders |
±1 mm |
Measuring Range |
0.5% – 100% Full Scale |
Load Unit |
Gf, kgf, N, kN, Lbf, etc. |
Voltage Supply |
220 – 240 V AC, 50 – 60 Hz, 1 ph |
In stock
Brand |
Nl Test |
---|---|
Model number |
NL 6000 X / 014HS |
Load Capacity |
600 kN |
Machine Class |
Class 1 |
Max. Compression Space |
600 mm |
Max. Tensile Space |
700 mm |
Piston Stroke |
200 mm |
Relative Error of Indicated Value |
±1% |
Effective Measurement Range |
1% – 100 % F S (Full Range without binning) |
Deformation Measurement Range |
1% – 100 % F S |
Relative Error of Deformation Indication |
±1% |
Relative Error of Displacement Indication |
±1% |
Relative Error of Stress Rate Control |
±2% |
Relative Error of Displacement Rate Control |
±1% |
Strain Rate Control Adjustment Range |
0.00025/s / 0.0025/s |
Relative Error of Strain Rate Control |
±2% |
Force, Deformation, & Displacement Retention Control |
0.3% – 100% F S |
Relative Error of Force, Deformation & Displacement Retention Control |
≤1% |
Girder Lifting Speed |
320 mm / min |
Effective Distance Between 2 Column |
455 mm |
Round Specimen Size |
Ø13 – Ø40 mm |
Flat Specimen Size |
Max. 20 mm Thick |
Size of Compression Platen |
Ø200 mm |
Dimension (Frame) |
900(L) x 700(W) x 2390(H) mm |
Dimension ( Control Console) |
790(L) x 730(W) x 1600(H) mm |
Weight (Control Console) |
300 kg |
Weight ( Frame) |
2650 kg |
Voltage Supply |
220 – 240 V AC, 50 – 60 Hz, 1 ph |
In stock
Weight | 120 kg |
---|---|
Dimensions | 62 × 40 × 136 cm |
Brand |
Nl Test |
Model number |
TT 6000 X / 021N |
Max Test Force |
3 kN |
Structure Type |
Single Rigid Column with Single High Precision Ball Screw (Desk Top Version) |
Trailing Space |
950 mm (exclude fixtures) |
Width Space |
350 mm |
Test Force Accuracy |
±0.8% |
Test Speed Range |
0.01 – 500 mm/min |
Load Resolution |
1/100 000 |
Force Accuracy |
≤0.5% |
Displacement Resolution |
1/1000 |
Displacement Accuracy |
≤0.5% |
Resolution of Metal Extenders |
1/1000 |
Accuracy of Metal Extenders |
≤0.5% |
Accuracy of Extenders |
±1 mm |
Measuring Range |
0.5% – 100% Full Scale |
Load Unit |
Gf, kgf, N, kN, Lbf, etc. |
Voltage Supply |
220 – 240 V AC, 50 – 60 Hz, 1 ph |
In stock
Weight | 120 kg |
---|---|
Dimensions | 62 × 40 × 136 cm |
Brand |
Nl Test |
Model number |
TT 6000 X / 021ND |
Max Test Force |
3 kN |
Structure Type |
Single Rigid Column with Single High Precision Ball Screw (Desk Top Version) |
Trailing Space |
950 mm (exclude fixtures) |
Width Space |
350 mm |
Test Force Accuracy |
±0.8% |
Test Speed Range |
0.01 – 500 mm/min |
Load Resolution |
1/100 000 |
Force Accuracy |
≤0.5% |
Displacement Resolution |
1/1000 |
Displacement Accuracy |
≤0.5% |
Resolution of Metal Extenders |
1/1000 |
Accuracy of Metal Extenders |
≤0.5% |
Accuracy of Extenders |
±1 mm |
Measuring Range |
0.5% – 100% Full Scale |
Load Unit |
Gf, kgf, N, kN, Lbf, etc. |
Voltage Supply |
220 – 240 V AC, 50 – 60 Hz, 1 ph |
No account yet?